cyberpower/registerups/registerups.cfg.example

42 lines
1.1 KiB
Plaintext

[UPS]
# IP addres or hostname of UPS SNMP card
address = 192.168.0.105
# TCP port
port = 3052
# Secret phrase for software authentication. This value must be the
# same as configured on the UPS web interface
# (System -> Authentication - > Software Authentication -> Secret Phrase)
secret_key = powerpanel.encryption.key
[HOST]
# IP address of the host to register
ip_address = 192.168.0.3
# Time needed for host shutdown
shutdown_time = 3
# Delay time
delay_time = -1
# I don't konwn what is bedt
bedt = 0
# Name of the host to register
hostname = server.local
# Host location
location = Server Room
# Contact
contact = System Administrator (sysadmin@example.net)
# Outlet number
outlet_id = 1
# isps - host type, true for Power Panel Remote, false for Power Panel Management
isps = true
# Outlet bank
bank_id = 1
# I don't known what is sa, default value in PPBE is 1, but 0 is old behavior(?)
sa = 0
# Shutdown condition
# b - low battery
# r - runtime insufficient
# u - power failure
# You can combine a value for this parameter
# Example with two shutdown conditions (low battery and runtime insufficient):
# event = br
event = b